background image

©20

21

 Dust Free® • All rights reserved. •   212731-00  Rev. 

3A

  

2

/

21

BIO-FIGHTER

4Xtreme 21", 33", 45"

Ultraviolet Light Systems

P/N

4Xtreme 21"

#06159

4Xtreme 33"

#06160

4Xtreme 45"

#06168

®

GENERAL

This product is designed to help disinfect the 
internal surfaces of heating, ventilation, and air 
conditioning systems where the light shines. 
Bacteria and viruses that are in the air stream that 
pass through the system can also be reduced. The 
result is an improved level of indoor air quality for 
occupants and improved system hygiene.

The Bio-Fighter® emits ultraviolet(UV-C) radiation

 

at a frequency of 254 nanometers, which has been

 

proven effective in damaging the DNA of 
microorganisms such as viruses, bacteria, 
yeast and

 

molds. This process either destroys 

the microorganism or neutralizes its ability to 
reproduce.

FEATURES

Reduces or prevents mold growth on HVAC coils, 

allowing them to operate at peak efficiency where 
the light shines. Also significantly reduces 
bacteria, viruses, fungi, and yeasts on surfaces 
exposed to the UV-C energy.

• NEMA 4X weatherproof enclosure.

• High output, long life UV-C lamps.

• Multi-voltage electronic ballast.

• Low maintenance and reduced costs.

INCLUDED INSIDE BOX

• Bio-Fighter® 4Xtreme ultraviolet light system

(UV-C lamp shipped separately.)

• Installation & operation manual
• UV-C warning label for duct

TOOLS REQUIRED FOR INSTALLATION

• Electric drill
• Phillips screw bit or screwdriver
• 1.125"-1.25" uni-bit or holecutter
• 3/32" drill bit
• Weatherproof conduit & conduit connector
• Weatherproof sealant
• Cotton cloth and rubbing alcohol
• Eye protection

BEFORE INSTALLING

• Read all instructions carefully. Failure to do

so could damage the equipment or cause
harm to yourself or others.

• Read all warnings and cautions.

• Only qualified technicians should perform

the installation.

Installation & Operation Manual

PO Box 519
Royse City, TX 75189
PH: 1-972-635-9564
Http://www.dustfree.com 

Summary of Contents for BIO-FIGHTER 4Xtreme

Page 1: ...owth on HVAC coils allowing them to operate at peak efficiency where the light shines Also significantly reduces bacteria viruses fungi and yeasts on surfaces exposed to the UV C energy NEMA 4X weatherproof enclosure High output long life UV C lamps Multi voltage electronic ballast Low maintenance and reduced costs INCLUDED INSIDE BOX Bio Fighter 4Xtreme ultraviolet light system UV C lamp shipped ...

Page 2: ... 347 5 817 276 6 245 293 6 267 924 6 280 686 6 313 470 6 627 000 6 539 727 6 932 494 6 550 257 Specifications subject to change without notice 4Xtreme 21 20 4Xtreme 33 32 4Xtreme 45 44 4 25 8 11 56 SPECIFICATIONS EPA Device Manufacturer Establishment No 73316 TX 1 The product and technologies described are not medical devices and are not intended to diagnose treat cure or prevent any disease or il...

Page 3: ...rradiate an air filter to neutralize the microbiological matter on the air filter surface such as would be found in the return air drop of a basement application or in the return plenum of a horizontal system in an attic take precautions as described in note above and make sure the UV fixture is placed on the return side of the filter DO NOT INSTALL THE UV FIXTURE ON EITHER SIDE OF THE FILTER IN H...

Page 4: ...allation WARNING Fig 2 For vertical installations use either the straight lamp or tilt lamp configuration Note Removal of lower slide clip is required for straight lamp configuration Fig 1 For horizontal installations use the tilt lamp configuration for greater UV C exposure into the drain pan ENCLOSURE MOUNTING Fig 3 Tape the provided mounting template at the desired installation location Use thi...

Page 5: ...iance with all national and local electrical and mechanical codes Failure to do so will void Dust Free warranty CONDUIT INSTALLATION Fig 4 Remove the two cover retaining screws and swing open the cover to access ballast and wiring Install an appropriate weatherproof conduit on the side of the enclosure Drill points are marked on two sides of the enclo sure where it is safe for conduit installation...

Page 6: ...in its straight lamp con figuration the lower slide bracket must be removed After the lower slide bracket has been removed gently insert lamp into lamp hole and push upper slide bracket over the retaining lip of the lamp and tighten the two knurled nuts until the lamp is securely fastened Fig 7 After lower slide clip is removed slip upper slide bracket over retaining lip of lamp and tighten two kn...

Page 7: ...ner Do not incinerate LAMP DISPOSAL Dispose of your spent UV C lamps at your local recycling center You may also send your spent lamps in the same container you received your replacement lamps to Dust Free Lamp Reclamation 1112 Industrial Drive Royse City TX 75189 IF THE LAMP DOES NOT ILLUMINATE Check that the lamp connector is securely attached to lamp Check that the fuse is in good working order...

Page 8: ...UST FREE EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY WORKMAN SHIP OR FITNESS FOR A PARTICULAR USE If the limited warranty is void due to failure to use a quali fied contractor all disclaimers of implied warranties shall be effective upon installation How to make a warranty claim or have questio...

Reviews: