background image

TILT-LAMP INSTALLATION 

(Fig.6 )

To maximize the efficiency and life of the UV-C
lamp, clean each lamp prior to installation.
Use isopropyl alcohol and cotton cloth to wipe
dust and fingerprints from the lamp.

Gently insert the lamp into the lamp hole.
While holding the lower slide bracket under
the retaining lip of the lamp, push the upper
slide bracket over the retaining lip of the lamp
and tighten the two knurled nuts until the lamp
is securely fastened.

Fig. 6

Hold lower slide bracket in place under lamp retaining lip

while pushing upper slide bracket over lamp retaining lip. Secure
with two knurled nuts.

Mercury Hazard. Do Not Break.

Each UV-C lamp contains a small amount of
Mercury. May cause redness or irritation. Use
proper disposal techniques in case of breakage. 

WARNING

UV-C Light Hazard.

UV-C light can cause temporary or permanent
loss of vision, and sunburn. Take precautions
to protect eyes and skin from direct exposure.

WARNING

BIO-FIGHTER® 4XTREME INSTALLATION & OPERATION MANUAL

5

IMPORTANT:

The device must be installed in compliance
with all national and local electrical and
mechanical codes. Failure to do so will void
Dust Free® warranty.

CONDUIT INSTALLATION 

(Fig.4 )

Remove the two cover retaining screws and
swing open the cover to access ballast and
wiring. Install an appropriate weatherproof
conduit on the side of the enclosure. 

Drill

points are marked on two sides of the enclo-
sure where it is safe for conduit installation.

Connect the electrical service, through the
conduit, to the ballast wires. Connect the black
and white wires to power and the green wire to
ground. Refer to Fig. 5 for wiring diagram.

Conduit installa-
tion points indi-
cated by dimples
on outside of
enclosure.

Fig. 4

Install weatherproof electrical conduits at either of the loca-

tions marked by dimples on the outside of the enclosure.

Fig. 5

Wiring diagram.

Electrical shock hazard.

Can cause injury or death. Before perform-
ing any service or maintenance disconnect
electrical service to the unit.

WARNING

White Wire

Black Wire

Green Wire

To 120V -  240V
Electrical Service

Ballast

To Ground

Lower slide bracket

Lamp retaining lip

Lower slide bracket

Lamp retaining lip

Important: 

O-ring

must be between slide
brackets to prevent
damage to ceramic
lamp base.

Upper slide bracket

Upper slide bracket

Summary of Contents for BIO-FIGHTER 4Xtreme

Page 1: ...owth on HVAC coils allowing them to operate at peak efficiency where the light shines Also significantly reduces bacteria viruses fungi and yeasts on surfaces exposed to the UV C energy NEMA 4X weatherproof enclosure High output long life UV C lamps Multi voltage electronic ballast Low maintenance and reduced costs INCLUDED INSIDE BOX Bio Fighter 4Xtreme ultraviolet light system UV C lamp shipped ...

Page 2: ... 347 5 817 276 6 245 293 6 267 924 6 280 686 6 313 470 6 627 000 6 539 727 6 932 494 6 550 257 Specifications subject to change without notice 4Xtreme 21 20 4Xtreme 33 32 4Xtreme 45 44 4 25 8 11 56 SPECIFICATIONS EPA Device Manufacturer Establishment No 73316 TX 1 The product and technologies described are not medical devices and are not intended to diagnose treat cure or prevent any disease or il...

Page 3: ...rradiate an air filter to neutralize the microbiological matter on the air filter surface such as would be found in the return air drop of a basement application or in the return plenum of a horizontal system in an attic take precautions as described in note above and make sure the UV fixture is placed on the return side of the filter DO NOT INSTALL THE UV FIXTURE ON EITHER SIDE OF THE FILTER IN H...

Page 4: ...allation WARNING Fig 2 For vertical installations use either the straight lamp or tilt lamp configuration Note Removal of lower slide clip is required for straight lamp configuration Fig 1 For horizontal installations use the tilt lamp configuration for greater UV C exposure into the drain pan ENCLOSURE MOUNTING Fig 3 Tape the provided mounting template at the desired installation location Use thi...

Page 5: ...iance with all national and local electrical and mechanical codes Failure to do so will void Dust Free warranty CONDUIT INSTALLATION Fig 4 Remove the two cover retaining screws and swing open the cover to access ballast and wiring Install an appropriate weatherproof conduit on the side of the enclosure Drill points are marked on two sides of the enclo sure where it is safe for conduit installation...

Page 6: ...in its straight lamp con figuration the lower slide bracket must be removed After the lower slide bracket has been removed gently insert lamp into lamp hole and push upper slide bracket over the retaining lip of the lamp and tighten the two knurled nuts until the lamp is securely fastened Fig 7 After lower slide clip is removed slip upper slide bracket over retaining lip of lamp and tighten two kn...

Page 7: ...ner Do not incinerate LAMP DISPOSAL Dispose of your spent UV C lamps at your local recycling center You may also send your spent lamps in the same container you received your replacement lamps to Dust Free Lamp Reclamation 1112 Industrial Drive Royse City TX 75189 IF THE LAMP DOES NOT ILLUMINATE Check that the lamp connector is securely attached to lamp Check that the fuse is in good working order...

Page 8: ...UST FREE EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY WORKMAN SHIP OR FITNESS FOR A PARTICULAR USE If the limited warranty is void due to failure to use a quali fied contractor all disclaimers of implied warranties shall be effective upon installation How to make a warranty claim or have questio...

Reviews: