Quick Install Guide

Retrofit compatibility

If you are replacing an existing EVCS system with this unit then a test 

for compatibility must be carried out on the outstations, and any units 

which do not function as expected must be replaced with new units. 

This advice also applies to all roaming handsets.

Installation

1.  Using a Phillips head screwdriver, open the front cover by 

removing the 2 screws along the bottom edge of the panel. 

Then lift the cover from the bottom edge and push up in order 

to disengage the latching clips on the top edge.

2.  Before mounting the VoCALL 5 on the wall it is advisable to 

remove the cable knockouts. Unused knockouts must be left 

unopened to comply with the Low Voltage Directive (LVD), 

accidentally knocked out holes should be blanked off.

3.  Fix the back box to the wall using the measurements provided 

below. Do not drill through the back box to the wall as this will 

contaminate the circuitry.

Knockouts

Top: 9 x 20mm

 CAUTION 

DO NOT power up the unit on batteries as the power 

supply has a large reservoir capacitor which may rupture 

the battery fuse if the AC is not present when powering 

up the system.

1

.

2

.

3

.

4.  Wire the mains connection according to the 

diagram overleaf.

5.  Wire the outstations according to the diagram overleaf.
6.  Finally, wire the batteries according to the 

diagram overleaf.

otee:

N

The VoCALL 5 is supplied without batteries which should 

 

be procured separately and be of adequate capacity to 

 

meet local regulations.