—————— Instruction manual ——————
347
Base omega
Value in [rpm] corresponding to the maximum angular speed of the winder/unwinder
(motor shaft side).
Vp=
π
x
Φ
min x
ω
x R
where :
Vp= peripheral speed
Φ
min=winder minimum diameter (mm)
ω
= motor angular speed
R =reduction ratio
ω
=Vp/
π
x
Φ
min x R=400/(3.14 x 0.1 x 0.5)=2547rpm
Base omega =set 2547rpm.
Ref speed thr
Line speed detecting threshold in %.
When “Line speed” is lower than “Line speed thr” the diameter calculation is disabled.
When “Line speed” is higher than the threshold, the diameter calculation is enabled with
an initial filter corresponding to
Diam init filter
for the time set in
Diam stdy delay
.
At the end of this time the filter is set to
Diam filter
.
Maximum line speed =400m/min . Line speed thr=5% (the diameter calculation is
automatically enabled at 20m/min).
Setting of the parameters in the SPEED DEMAND menu
PARAMETERS
OPTION Menu
————> Torque winder
————> Speed demand
Speed demand En
Enabling of the speed reference calculation; set
Enable
Winder side
Selection of the winding/unwinding side. Selection to be carried out only if the digital
inputs are not set.
0 =up,
1 =down
W gain
Setting of the speed reference gain used for the loop saturation. Parameter given as a
percentage of the increase/decrease of the angular speed reference.
W gain
=30% (set this starting value)
W offset
Offset setting on the speed reference for the winder/unwinder initial phase with a stopped
line. Parameter in [rpm].
W offset
=50rpm (check with the material)
Offset acc time
Setting of the initial phase ramp with a stopped machine. Parameter in [s]. The acc time
refers to the parameter
speed base value
W target
Parameter number which the speed reference has to be addressed to. In order to obtain the
real number to be set it is necessary to add +2000H (8192 decimal) to the parameter number.
W target
: set 2 as a speed reference:
OPTION Menu
————> Torque winder
————> Speed demand
————> W target = 8235
Paragraph 10.2.
“List of the high priority parameters’
shows that
Speed ref 2
has the
decimal number 43. In order to obtain the value to be entered add 8192 decimal (fixed
offset): 8192 + 427 = 8235
Summary of Contents for TPD32-EV-...-2B
Page 1: ... Instruction manual Industrial Application DC drives TPD32 EV ...
Page 372: ... TPD32 EV 372 9 BLOCK DIAGRAM 9 1 CONTROL BLOCK DIAGRAMS ...
Page 373: ... Instruction manual 373 ...
Page 374: ... TPD32 EV 374 ...
Page 375: ... Instruction manual 375 ...
Page 376: ... TPD32 EV 376 ...
Page 377: ... Instruction manual 377 ...
Page 378: ... TPD32 EV 378 ...
Page 379: ... Instruction manual 379 ...
Page 380: ... TPD32 EV 380 ...
Page 381: ... Instruction manual 381 ...
Page 382: ... TPD32 EV 382 ...
Page 383: ... Instruction manual 383 ...
Page 384: ... TPD32 EV 384 ...
Page 385: ... Instruction manual 385 ...
Page 386: ... TPD32 EV 386 ...
Page 387: ... Instruction manual 387 ...
Page 388: ... TPD32 EV 388 ...
Page 389: ... Instruction manual 389 ...
Page 390: ... TPD32 EV 390 ...
Page 391: ... Instruction manual 391 ...
Page 392: ... TPD32 EV 392 ...
Page 393: ... Instruction manual 393 ...
Page 394: ... TPD32 EV 394 ...
Page 395: ... Instruction manual 395 ...
Page 396: ... TPD32 EV 396 ...
Page 397: ... Instruction manual 397 ...
Page 398: ... TPD32 EV 398 ...
Page 399: ... Instruction manual 399 ...
Page 400: ... TPD32 EV 400 ...
Page 401: ... Instruction manual 401 ...
Page 402: ... TPD32 EV 402 ...
Page 501: ... Instruction manual 501 APPENDIX 3 ACCESSORIES A3 1 EAM Adapter Kit EAM1579 EAM1580 ...
Page 503: ......