—————— TPD32-EV ——————
136
6 - FUNCTION DESCRIPTION
Functions and parameters
The converters of the TPD32-EV series feature a number of functions that can be set and assigned parameters
in order to meet the requirements of the application at hand.
The device can be controlled in different ways:
- via the terminal strip
- via the keypad
- via the RS 485 serial interface
- via a bus connection (option)
The settings required are made via the
Main commands
and
Control mode
parameters in the CONFIGU
-
RATION menu.
The device is supplied with a Windows
TM
-based user interface software for controlling the drive and setting
parameters via the RS 485 serial interface.
The device is factory set for speed regulation with a cascade current regulation and is connected according to the
connection diagram shown on in section 4.8, “Standard connection diagrams”. Only the entry of parameters in
the START UP of the software is required for the initial commissioning of the drive. The drive is thus controlled
via the terminal strip with all parameters set via the keypad.
If functions are required that are not in the standard configuration, these can be selected and their parameters set
accordingly via the appropriate menu.
The TBO option card is required for expanding the standard device with programmable inputs/outputs. Up to
no. 2 TBOs can be fitted, each providing 4 digital inputs, 4 digital outputs and 2 analog outputs. Three analog
inputs are provided on the standard device.
The converters of the TPD32-EV series enable reference values for the ramp and for the speed regulator to be
set in different units of measure:
- in percentages of the
Speed base value
- in a unit of measure (dimension) that the user can define using the factor function, e.g. as speed in m/s.
According to which one is set as last the other will be updated. This means that the other reference value is
overwritten with the current value.
A freely selectable password 1 prevents the operation of the converter by unauthorized persons. It is entered in
the form of a five-digit number combination. Password 2 is also provided by the manufacturer. This password
enables the service personnel to access the Service menu which is not accessible for the user.
n
ote
!
All parameter settings must be saved otherwise the last settings saved will be loaded the next
time the device is switched on (Save parameters command)
Summary of Contents for TPD32-EV-...-2B
Page 1: ... Instruction manual Industrial Application DC drives TPD32 EV ...
Page 372: ... TPD32 EV 372 9 BLOCK DIAGRAM 9 1 CONTROL BLOCK DIAGRAMS ...
Page 373: ... Instruction manual 373 ...
Page 374: ... TPD32 EV 374 ...
Page 375: ... Instruction manual 375 ...
Page 376: ... TPD32 EV 376 ...
Page 377: ... Instruction manual 377 ...
Page 378: ... TPD32 EV 378 ...
Page 379: ... Instruction manual 379 ...
Page 380: ... TPD32 EV 380 ...
Page 381: ... Instruction manual 381 ...
Page 382: ... TPD32 EV 382 ...
Page 383: ... Instruction manual 383 ...
Page 384: ... TPD32 EV 384 ...
Page 385: ... Instruction manual 385 ...
Page 386: ... TPD32 EV 386 ...
Page 387: ... Instruction manual 387 ...
Page 388: ... TPD32 EV 388 ...
Page 389: ... Instruction manual 389 ...
Page 390: ... TPD32 EV 390 ...
Page 391: ... Instruction manual 391 ...
Page 392: ... TPD32 EV 392 ...
Page 393: ... Instruction manual 393 ...
Page 394: ... TPD32 EV 394 ...
Page 395: ... Instruction manual 395 ...
Page 396: ... TPD32 EV 396 ...
Page 397: ... Instruction manual 397 ...
Page 398: ... TPD32 EV 398 ...
Page 399: ... Instruction manual 399 ...
Page 400: ... TPD32 EV 400 ...
Page 401: ... Instruction manual 401 ...
Page 402: ... TPD32 EV 402 ...
Page 501: ... Instruction manual 501 APPENDIX 3 ACCESSORIES A3 1 EAM Adapter Kit EAM1579 EAM1580 ...
Page 503: ......