—————— TPD32-EV ——————
178
configured the analog output and the digital inputs needed for its operation. If
2B+E
mode is not enabled only
Wired FC EN
digital input is needed, if
2B+E
mode is enabled also digital inputs
Wired FC Inv Seq
and
Wired FC Act Brg
are needed.
Suggested I/O configuration
TPD32-EV
IPA 66
Select output 1
IPA 139
Digital Input 3
IPA 138
Digital Input 2
IPA 137
Digital Input 1
[95]
Field cur ref
[90]
Wired FC Act Brg
[89]
Wired FC Inv Seq
[88]
Wired FC EN
21
33
32
31
1
28
27
26
[6]
T current ref 1
[82]
Wired FC Act Brg
[81]
Wired FC Inv Seq
[80]
Wired FC EN
IPA 70
Select input 1
IPA 147
Digital Output 3
IPA 146
Digital Output 2
IPA 145
Digital Output 1
TPD32-EV-FC
Enable flux weak
Command for
Voltage control
.
ON
The field current corresponds to the value set via the
Flux cur-
rent min
parameter.
OFF
The field current is regulated on the basis of the functioning
mode and on the drive working setpoint.
Speed-0 f weak
When this function is enabled, and the speed 0 threshold is reached, it will be produced
the minimum field current set via
Flux current min
.
Supposing that:
Start
= Low level and/or
Fast stop
= Low level
Set as field economy:
To avoid the overheating of motors which should not run or to avoid the presence of conden
-
sation in motor which work externally ( the field will be used as anti condensation heating).
ON
Enabled function
OFF
Disabled function
Flux reference
Flux/current reference : the 100% corresponds to the
Motor nom flux
parameter.
With the function Flux / if curve defined, this reference corresponds to the flux reference.
With the function Flux / if curve not defined (default conditions), this reference cor
-
responds to the field current reference.
Flux curr (%)
Field current feedback, expressed as percentage of the
Motor nom flux
parameter.
Out vlt level
Percentage of the maximum output voltage according to the
Max out voltage
parameter.
This parameter allows the changing of the output voltage in “Voltage control”
(FLUX REGULATION\Flux reg mode).
FC cur ref hyst
Parameter of the “Three-phase external exciter control” function, see "A2.5 External
Three-phase Field Exciter Control" on page 493.
This parameter can be used to avoid continuous reversal of field current polarity when
the motor is running with no load or a limited load applied and thus with a Speed reg
output value that is almost null.
I field cnst 40
Current value at 40% of flux (see Flux /if curve, paragraph 5.3.7)
I field cnst 70
Current value at 70% of flux (see Flux /if curve, paragraph 5.3.7)
I field cnst 90
Current value at 90% of flux (see Flux /if curve, paragraph 5.3.7)
Set flux / if
Command for the setting of the flux curve according to the setting of
I field cnst 40-70-
90
parameter. With the defined curve, the meaning of
Flux current max/Flux refer-
ence
indicates only the flux percentage according to the characteristic of this curve. As
Summary of Contents for TPD32-EV-...-2B
Page 1: ... Instruction manual Industrial Application DC drives TPD32 EV ...
Page 372: ... TPD32 EV 372 9 BLOCK DIAGRAM 9 1 CONTROL BLOCK DIAGRAMS ...
Page 373: ... Instruction manual 373 ...
Page 374: ... TPD32 EV 374 ...
Page 375: ... Instruction manual 375 ...
Page 376: ... TPD32 EV 376 ...
Page 377: ... Instruction manual 377 ...
Page 378: ... TPD32 EV 378 ...
Page 379: ... Instruction manual 379 ...
Page 380: ... TPD32 EV 380 ...
Page 381: ... Instruction manual 381 ...
Page 382: ... TPD32 EV 382 ...
Page 383: ... Instruction manual 383 ...
Page 384: ... TPD32 EV 384 ...
Page 385: ... Instruction manual 385 ...
Page 386: ... TPD32 EV 386 ...
Page 387: ... Instruction manual 387 ...
Page 388: ... TPD32 EV 388 ...
Page 389: ... Instruction manual 389 ...
Page 390: ... TPD32 EV 390 ...
Page 391: ... Instruction manual 391 ...
Page 392: ... TPD32 EV 392 ...
Page 393: ... Instruction manual 393 ...
Page 394: ... TPD32 EV 394 ...
Page 395: ... Instruction manual 395 ...
Page 396: ... TPD32 EV 396 ...
Page 397: ... Instruction manual 397 ...
Page 398: ... TPD32 EV 398 ...
Page 399: ... Instruction manual 399 ...
Page 400: ... TPD32 EV 400 ...
Page 401: ... Instruction manual 401 ...
Page 402: ... TPD32 EV 402 ...
Page 501: ... Instruction manual 501 APPENDIX 3 ACCESSORIES A3 1 EAM Adapter Kit EAM1579 EAM1580 ...
Page 503: ......