—————— TPD32-EV ——————
226
6.13.3 Speed control
ADD SPEED FUNCT
Speed control
[101]
Spd thr [FF]
[102]
Spd threshold - [FF]
[103]
Threshold delay [ms]
[104]
Set error [FF]
[105]
Set delay [ms]
Two speed control messages are provided:
-
when a particular, adjustable speed is not exceeded.
-
when the speed corresponds to the set rference value
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
Standard
Spd thr [FF]
101
1
32767
1000
1000
-
Spd threshold - [FF]
102
1
32767
1000
1000
-
Threshold delay [ms]
103
0
65535
100
100
-
Spd threshold
Speed exceeded (0)
Speed not exceeded (1)
393
0
1
Digital output 3 *
Set error [FF]
104
1
32767
100
100
-
Set delay [ms]
105
1
65535
100
100
-
Set speed
Speed not ref. val. (0)
Speed = ref. val. (1)
394
0
1
-
* This function can be assigned to a programmable digital output.
Spd thr
Switch point for the “Speed not exceeded” for clockwise rotation of the drive in the
units defined by the Factor function.
Spd threshold -
Switch point for the “Speed not exceeded” for counter-clockwise rotation of the drive
in the units defined by the Factor function.
Threshold delay
Setting of a delay time in milliseconds which is active when the speed is lowered within
the limits of the set threshold.
Spd threshold
Message “Set speed not exceeded” (via a programmable digital input)
High Speed not exceeded
Low Speed exceeded
Set error
Defines a tolerance band around the speed reference in the units specified by the Factor function.
Set delay
Setting of a delay time in milliseconds which is active when the speed is lowered within
the limits of the set threshold.
Set speed
Message “The speed corresponds to the reference value” (via a programmable digital output)
High Speed corresponds to the reference value
Low Speed does not corresponds to the reference value
The message “The speed corresponds to the reference value” refers to the total reference value in front of the
Speed ref
speed regulator and to the
Ramp Ref
ramp reference when the ramp is selected.
When the references are lower than ± 1 %, the signal is always low!
Summary of Contents for TPD32-EV-...-2B
Page 1: ... Instruction manual Industrial Application DC drives TPD32 EV ...
Page 372: ... TPD32 EV 372 9 BLOCK DIAGRAM 9 1 CONTROL BLOCK DIAGRAMS ...
Page 373: ... Instruction manual 373 ...
Page 374: ... TPD32 EV 374 ...
Page 375: ... Instruction manual 375 ...
Page 376: ... TPD32 EV 376 ...
Page 377: ... Instruction manual 377 ...
Page 378: ... TPD32 EV 378 ...
Page 379: ... Instruction manual 379 ...
Page 380: ... TPD32 EV 380 ...
Page 381: ... Instruction manual 381 ...
Page 382: ... TPD32 EV 382 ...
Page 383: ... Instruction manual 383 ...
Page 384: ... TPD32 EV 384 ...
Page 385: ... Instruction manual 385 ...
Page 386: ... TPD32 EV 386 ...
Page 387: ... Instruction manual 387 ...
Page 388: ... TPD32 EV 388 ...
Page 389: ... Instruction manual 389 ...
Page 390: ... TPD32 EV 390 ...
Page 391: ... Instruction manual 391 ...
Page 392: ... TPD32 EV 392 ...
Page 393: ... Instruction manual 393 ...
Page 394: ... TPD32 EV 394 ...
Page 395: ... Instruction manual 395 ...
Page 396: ... TPD32 EV 396 ...
Page 397: ... Instruction manual 397 ...
Page 398: ... TPD32 EV 398 ...
Page 399: ... Instruction manual 399 ...
Page 400: ... TPD32 EV 400 ...
Page 401: ... Instruction manual 401 ...
Page 402: ... TPD32 EV 402 ...
Page 501: ... Instruction manual 501 APPENDIX 3 ACCESSORIES A3 1 EAM Adapter Kit EAM1579 EAM1580 ...
Page 503: ......