SOFTWARE MANUAL C32
8.12.1.1 READ STATISTIC VALUES in A8 format
identifier
measurement value
granularity
0
operation time
1 minute
1
mileage
3 cm
2
power on
1
3
cuts
1
4
head up
1
5
paper end
1
6
EoT command
1
8.12.2 READ STATISTIC VALUES VIA MESSAGE COMMAND
The message output of the measured variable is always 8 digits in ASCII-hex format using the message command.
[Example]
message command for query of cuts: <ESC>x<1d><15d><3d>
[Output]
Number of cuts: 2DB4h = 11700
1Bh 78h 30h 46h 30h 33h 30h 38h 00h 00h 00h 00h 32h 44h 42h 34h
<ESC> x 0 F 0 3 0 8 0 0 0 0 2 D B 4