SOFTWARE MANUAL C32
23 ATTACHMENT B: ADVANCED C32 DEBUG STATUS MESSAGE
The advanced C32 debug status message is intended for diagnose and support. GeBE reserves the right for any changes like flag
assignments. For your application apply the C32 standard status messages.
23.1 ENABEL/DISABLE ADVANCED C32 STATUS MESSAGE
The advanced C32 status message can be enabled/disabled in parameter 12,5.
Parameter:
12,5:
1: enable / 0: disable debug status messages
12,6:
periodical debug status message in [ms] / 0: disabled
23.2 MESSAGE STRUCTURE
[AI
Length
#[
Timestamp
ms
GMID
:
Pos_Counter
,
PM,SysParams,HostIF,Print,Print_Sensors,Print_EoT,
Renderer#i__
]#0x
CRC
:AI]
Example:
Output in ASCII format:
[AI
0x00000052
#[
0x0000000E
ms
0x000C0000
:
0x00000001
,
0x00000001,0x00000000,0x0000BE40,0x00000001,0x00000000,0x00000000,0x00
000000#i__
]#
0x2D500C85
:AI]
Pos counter: Line counter since printer switch-on (32 bit counter ).
23.3 MODULE PM POWER MANAGER
Bit
Description
0
All modules in operative status
1
Emergency operation with factory set parameters
2
Imminent power off
3
Fast charging
4
Trickle charging
5
Battery fully charged
6
Suspend
7
Resume
8 – 31 Not used = 0
23.4 MODULE SysParams
Bit
Description
0
Module is active
1
EEPROM access not possible
2
at least 1 EEPROM system parameter set destroyed
3
at least 1 EEPROM system parameter set damaged
4
at least 1 Factory system parameter set damaged
5 – 31 Not used = 0
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 157 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.