SOFTWARE MANUAL C32
5.2 LIST OF PRINTER PARAMETERS
Module 3
Power Manager
3,1
u_a
Idle time [s] power off time (depending on hardware) 0 =: off
10 - 32000 in seconds to turn off after the last action
Module 9
Host I/F
9,1
e_w
number of data items sent from data host to receiving queue
9,2
e_w
placed bit: activates the GeBE ASCII protocol
Module 10
RS232
10,1
r/o
interface
1= disabled / 2= enabled
10,2
u_w
baud rate
0: 115200 baud (default)
1: 921600 baud
2: 460800 baud
3: 230400 baud
4: 115200 baud
5: 57600 baud
6: 38400 baud
7: 19200 baud
8: 9600 baud
9: 4800 baud
10: 2400 baud
11: 1200 baud
on demand:
12: 600 baud
255: 3,686,400 baud
254: 1,843,200 baud
10,4
u_w
parity
2= even / 1= odd,
0= no parity
10,5
u_w
stop bits
1= 2 stop bits /
0= 1 stop bit
10,6
u_w
f
low control CTS host printer
→
1= CTS enable /
0= CTS disable
10,7
u_w
transmit to host
1= enabled
/ 0= disabled
Module 11
USB
11,1
r/o
set bit: interface not present /other: interface present
11,2
u_a
Redirected GeBE_C32 status flag at bit index 0/0
11,3
u_a
Redirected GeBE_C32 status flag at bit index 1/0
11,4
u_a
Redirected GeBE_C32 status flag at bit index 2/0
11,5
u_a
Redirected GeBE_C32 status flag at bit index 6/0
11,6
u_a
Redirected GeBE_C32 status flag at bit index 7/0
11,7
u_a
USB reset
0= standard / 1= USB reset adjustable
11,8
u_a
USB reset approach
reset number, see also chapter 6 „Initialize printer“
11,9
u_a
0: no keepalive signal required
Deactivation of running watchdog triggers POR/ any other value: keepalive period [s]
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 20 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.