10 PRINT POWER MANAGEMENT IN CONSTANT SPEED MODE
In test mode, the printer control is carried out via the fixed specification of cycle time of a print line and the indication of
the heating time .
Parameter
:
18,32
fixed S.L.T. [µs], 0: variable S.L.T.
Parameter 18,32
defines the cycle time of a dotline and thus the printing speed. TSLT is active as soon as a
value is > 0. In this case, the indication of the printing speed in
parameter 18,3
is ineffective. Once this value
is given, the printer accelerates according to its acceleration ramp up to this speed and holds it . Acceleration
and reaching the set speed is displayed in the status byte 8.
ATTENTION: The printer stops immediately if necessary printing data for the dotline are not available on time!
Example: speed 250 mm/s at a resolution of 8 dot/mm (200 dpi) -> Tcyl = 1/(250*8) = 500 µs
18,29
fixed strobes on time [µs], 0: variable strobes on time
Parameter 18,29
defines the pressure energy (density) of the printout and is reported in microseconds. Typically
density 50% does not exceed Tcyl . If the
parameter 18,29
value is > 0, the
parameter 18,6 density
becomes
ineffective.
18,30
minimum strobes off time [µs]
Parameter 18,30
defines the minimum switch-off time of the dots within one cycle, in order not to overload the
heating elements. The parameter is specified in microseconds.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 81 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.