SOFTWARE MANUAL C32
5.1.3
PARAMETER ACCESS AUTHORISATION
u_a
User configuration:
Changes become effective immediately.
u_w
User configuration:
Changes become effective after a reset.
e_a
Expert configuration:
Not changeable by user, but by expert. Changes become effective immediately.
e_w
Expert configuration:
Not changeable by user, but by expert. Changes become effective after a reset.
r/o
Factory configuration only
5.1.4
EXAMPLES
1. Output of all EEPROM parameters (user settings) via host interface:
<RS>[12:0,0:0]
<1Eh><5Bh><31h><32h><3Ah><30h><2Ch><30h><3Ah><30h><5Dh>
„12“
copy EEPROM parameter to output
„0“
0 = all modules
„0“
parameter index (complete list)
„0“
digital output via interface
2. Delete all EEPROM parameters:
<RS>[4:0,0]
<1Eh><5Bh><34h><3Ah><30h><2Ch><30h><5Dh>
„4“
delete all EEPROM parameters
„0“
0 = all modules
„0“
parameter index (complete list)