SOFTWARE MANUAL C32
8.11 STATUS LED
Depending on the hardware equipment, a printer has 1 to 3 LEDs.
Status LED:
is the usual equipment. The color is typically green
Error LED
:
e.g. printer LAB shows serious errors
Option-LED:
typically the illuminated bezel. At printer Lab the LED indicates preheating head
Parameter 39,2
allows the setting of several flashing schematas:
Index
Status-LED
Error-LED
Option LED / BEZEL
0
off
off
if necessary,
control via command or EoT
1
- flashing in case of error
- otherwise permanently off
2
- flashing in case of error
- otherwise permanently off
3
off
4
- permanenty on at trickle charging
- long on / short off at quick charge
- otherwise short on / long off
- flashing in case of error
- otherwise permanently off
5
off
off
6
- flashing
in case of medium fatal error
- otherwise permanently on
- flashing
in case of medium fatal error
- otherwise permanently off
- permanently on
at preheated head
- long on / short off at preheat level 1
- otherwise short on / long off
7
permanently on
off
- permanently on
in case of very little error (HeadUp)
- fast flashing in case of error
- otherwise off
if necessary, control via command or
EoT