SOFTWARE MANUAL C32
7.5 DEFAULT STATUS MESSAGE VIA FLAGS CALLED A8 STATUS MESSAGE
7.5.1
STATUS MESSAGE REQUEST IN A8 MODE
[Name]
Request status
[Format]
ASCII
<ESC>
“k“
Hex
1Bh
6Bh
Decimal
27d
107d
[Description]
On receiving this command the printer controller sends the status bytes.
In module 30 Msg_GeBE_A8 the individual status bytes can be enabled and disabled.
30,1: T: enable / F: disable
1st status byte
30,2: T: enable / F: disable
2nd status byte
30,3: T: enable / F: disable
3rd status byte
30,4: T: enable / F: disable
4th status byte
30,5: T: enable / F: disable
5th status byte
30,6: the flag „no.“ of extended status messages is displayed in
status byte 4 Bit 0
30,7: the flag „no.“ of extended status messages is displayed in
status byte 4 Bit 1
30,8: the flag „no.“ of extended status messages is displayed in
status byte 4 Bit 2
30,9: the flag „no.“ of extended status messages is displayed in
status byte 4 Bit 3
30,10: the flag „no.“ of extended status messages is displayed in
status byte 5 Bit 0
30,11: the flag „no.“ of extended status messages is displayed in
status byte 5 Bit 1
30,12: the flag „no.“ of extended status messages is displayed in
status byte 5 Bit 2
30,13: the flag „no.“ of extended status messages is displayed in
status byte 5 Bit 3
[Example]
The status of sensor AUX7 should be displayed on status byte 5 Bit 0.
The extended status flag for AUX7 is current number 15.
1. First activate status byte 5 with
parameter 30,5
= T
2. Set
parameter 30,10
to 15.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 35 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.