CHAPTER 20 16-BIT RELOAD TIMER
20.1 Overview
■
Counter Operating Mode
●
Reload mode
When an underflow occurs in the 16-bit downcounter ("0x0000"
→
"0xFFFF"), the value of
the 16-bit reload timer reload register (TMRLRHn/TMRLRLn) is loaded to the 16-bit
downcounter and the 16-bit reload timer continues counting. In addition, since the interrupt
request is output by an underflow, the 16-bit reload timer can be used as the interval timer.
●
One-shot mode
An interrupt is generated when an underflow occurs on the 16-bit downcounter.
During counter operation, the TOn pin outputs a square waveform indicating that the counter is
currently running.