4-5. E: 18. Wireless LAN adapter non-energized
Indicator
Indoor unit
Operation indicator
1 time flash
Timer indicator
8 time flash
Economy indicator
Continuous flash
Error code
E: 18
Wireless LAN
adapter
LED1 (green)
Off
LED2 (orange)
Off
Detective actuator
Indoor unit controller PCB
When the voltage (DC 12 V) does not output from the
controller PCB.
Wireless LAN adapter PCB
Forecast of cause
Indoor unit controller PCB failure
Wireless LAN adapter PCB failure
Wiring connection failure
Check point 1. Check the connection.
•
Check any loose or removed connection of between the wireless LAN adapter PCB and con-
troller PCB.
-> If there is abnormal condition, correct it.
•
Check the connection condition on the controller PCB.
-> If there is loose connector, open cable or mis-wiring, correct it.
↓
Check point 2. Check the wireless LAN adapter PCB and the controller PCB
Check voltage at CN12 (terminal 1—2) of main PCB.
(Power supply to remote controller)
•
If it is DC 0 V, controller PCB is failure.
-> Replace controller PCB.
•
If it is DC 12 V, wireless LAN adapter PCB is failure.
-> Replace the wireless LAN adapter and cancel the registration of air condi-
tioner on the mobile app.
After replacing the adapter, perform the pairing on the mobile app.
For the method of the mobile app, refer to
↓
End
4-5. E: 18. Wireless LAN adapter non-energized
- (03-77) -
4. Troubleshooting with error code (For wireless LAN adapter)
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...