7. Various control
7-1. Auto restart
When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents
memorized when the power is
interrupted
Wall mounted (For KGTE, 18–
24KMTB, KMTE, KMCE, KETA, and
KETE),
Floor
Compact cassette,
Mini duct, Slim duct,
Medium static pressure duct,
Wall mounted (For KGTB, 07–
14KMTB, and KMCC),
Ceiling
Operation mode
○
○
Setting temperature
○
○
Fan mode setting
○
○
Timer mode and set time
(set by wireless remote
controller)
○
○
Airflow direction setting
○
○
Swing
○
○
ECONOMY operation
○
○
10 °C HEAT operation
○
○
Outdoor low noise operation
○
○
Remote control setting
○
—
WLAN indicator lamp setting
○
—
7-2. MANUAL AUTO operation
When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Wall mounted, Floor
Compact cassette,
Mini duct, Slim duct,
Medium static pressure duct,
Ceiling
Operation mode
Auto changeover
Fan mode
AUTO
Timer mode
Continuous (no timer setting available)
Setting temperature
24°C
Horizontal louver setting
Standard
According to memory position
Vertical louver setting
According to memory position
SWING
Off
ECONOMY
Off
Human sensor
Off
7-1. Auto restart
- (04-69) -
7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...