4-4. Individual louver control
¢
Compact cassette type
To independently can be set the airflow pattern of each louver as follows:
This function is given priority to overall louver control. But this function is release during the following
operation.
• Cold air prevention control
• Monitor mode on the auto change over operation
• Defrost operation
The air direction range will change as follows:
1
2
3
4
1
2
3
4
Use the wired remote controller to set this function. This function is only available by 2-wire remote
controller.
NOTE:
When the 2-wire remote controller is disconnected, clear the individual setting. Otherwise,
this setting can’t change.
4-5. All louver control
¢
Compact cassette type
•
All louver operation
When the mode is selected, the standard louver position of the each mode is set.
Operation mode
Standard Position
Cooling
1
Dry
1
Heating
4
Monitor
1
NOTES:
• Setting of the wireless remote controller is not displayed on the wired remote controller.
• The setting louver of the individual control function cannot be controlled.
4-4. Individual louver control
- (04-58) -
4. Louver control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...