Floor type
Fan speed
Indoor fan speed is defined as below.
• Model: AGHG09KVCA
Operation mode
Fan mode
(Upper/Lower)
Speed (rpm)
Upper & Lower air flow
mode
Upper air flow mode
Heating
POWERFUL
1,230/1,040
1,300/ —
HIGH
1,120/950
1,230/ —
MED+
1,000/850
1,090/ —
MED
1,000/850
1,090/ —
LOW-
860/730
940/ —
QUIET
660/560
790/ —
Cool air prevention
660/560
790/ —
S-LOW
660/560
790/ —
Cooling/Fan
POWERFUL
1,230/1,040
1,300/ —
HIGH
1,120/950
1,230/ —
MED
960/820
1,070/ —
LOW
820/700
910/ —
QUIET
660/560
790/ —
Soft quiet
570/480*
1
790/ —*
1
S-LOW
660/560*
2
790/ —*
2
Dry
X zone: — / —
J zone: — / —
X zone: 790/ —
J zone: 790/ —
*1: Fan mode only
*2: Cooling mode only
• Model: AGHG12KVCA
Operation mode
Fan mode
(Upper/Lower)
Speed (rpm)
Upper & Lower air flow
mode
Upper air flow mode
Heating
POWERFUL
1,350/1,150
1,370/ —
HIGH
1,240/1,040
1,300/ —
MED+
1,080/920
1,140/ —
MED
1,080/920
1,140/ —
LOW-
910/770
980/ —
QUIET
660/560
790/ —
Cool air prevention
660/560
790/ —
S-LOW
660/560
790/ —
Cooling/Fan
POWERFUL
1,350/1,150
1,370/ —
HIGH
1,240/1,040
1,300/ —
MED
1,050/890
1,120/ —
LOW
860/730
930/ —
QUIET
660/560
790/ —
Soft quiet
570/480*
1
790/ —*
1
S-LOW
660/560*
2
790/ —*
2
Dry
X zone: — / —
J zone: — / —
X zone: 790/ —
J zone: 790/ —
*1: Fan mode only
*2: Cooling mode only
3-1. Indoor fan control
- (04-49) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...