Page 1: ...if applicable Electrical shock can cause personal injury or death INSTALLATION RECOMMENDATIONS NOTE In some cases noise in the living area has been traced to gas pulsations from improper installation of equipmant I Locate unit away from windows patios decks and so forth where unit operation sound may disturb customer 2 Ensure that vapor and liquid tube diameters are appropriate to capacity of unit...

Page 2: ...d Maintain a distance of 24 in between units Position so water snow or ice from roof or eaves cannot tall directly on unit On rooftop applications locate unit at least 6 in above roof surface PROCEDURE 4 OPERATING AMBIENT OUTDOOR TEMPERATURES The minimum outdoor operating ambient in cooling mode is 55 F and the maximum outdoor operating ambient in cooling mode is 125 F PROCEDURE 5 REPLACE INDOOR C...

Page 3: ...unit rating plate for recommended circuit protection device_ NOTE Operation of unit on improper line voltage constitutes abuse and could affect unit reliability See unit rating plate Do not install unit in system where voltage or phase imbalance 3 phase may fluctuate above or below permissible limits NOTE Use copper wire only between disconnect switch and unit NOTE Install branch circuit disconnec...

Page 4: ...mostat to OFF mode and close electrical disconnect to outdoor unit CAUTION Service valve gage ports are equipped with Schrader valves To prevent personal injury wear safety glasses and gloves when handling refrigerant 2 Fully back seated open liquid and vapor service valves 3 Unit is shipped with valve stem s front seated closed and caps installed Replace stem caps after system is opened to refi i...

Page 5: ...ssor damage may occur if system is overcharged CAUTION Do not vent refrigerant to atmosphere Recover during system repair or final unit disposal CARE AND MAINTENANCE For continuing high performance and to minimize possible equipment failure it is essential that periodic maintenance be performed on this equipment Consult your servicing contractor or User s Manual for proper frequency of maintenance...

Page 6: ... STAGE 1 COOL STAGE 1 iNDOOR FAN _ M L_ J L I I_ i A01331 A01332 ACTHERMOSTAT SINGLE STAGE COO_HEAT 24 VAC HOT HEAT STAGE 1 COOL STAGE 1 iNDOOR FAN SINGLE STAGE AIR FURNACE CONDITIONER D AC THERMOSTAT SINGLE STAGE COOL HEAT PF AIR FAN COIL CONDITIONER A01333 24 VAC HOT _ HEATSTAGE 1 _ COOL STAGE 1 E_ INDOOR FAN E_ Fig 5 Typical 24v Circuit Connections A01334 __ J_t_ c 2003 Payne Heating Cooling 73...