![Fujitsu ABHG18KRTA Service Manual Download Page 340](http://html.mh-extra.com/html/fujitsu/abhg18krta/abhg18krta_service-manual_118013340.webp)
3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Compact cassette type
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
07
09
12
14
18
22
Heating
HIGH
590
590
650
830
830
880
MED+
570
570
620
770
770
850
MED
540
540
580
730
730
800
LOW
490
490
520
630
630
740
QUIET
440
440
460
500
500
580
Cool air
prevention
400
400
400
400
400
400
S-LOW
300
300
300
300
300
300
Cooling/Fan
HIGH
590
590
650
730
730
860
MED
540
540
580
630
630
770
LOW
490
490
520
540
540
650
QUIET
440
440
460
460
460
500
Soft quiet
400*
1
400*
1
400*
1
400*
1
400*
1
400*
1
S-LOW
300*
2
300*
2
300*
2
300*
2
300*
2
300*
2
Dry
X zone:
440
J zone:
440
X zone:
440
J zone:
440
X zone:
460
J zone:
460
X zone:
460
J zone:
460
X zone:
460
J zone:
460
X zone:
500
J zone:
500
*1: Fan mode only
*2: Cooling mode only
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-20) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...