Model name
ASHG07KETE
ASHG07KETE-B
ASHG09KETE
ASHG09KETE-B
ASHG12KETE
ASHG12KETE-B
ASHG14KETE
ASHG14KETE-B
Power supply
1Ø 230 V ~50 Hz
Available voltage range
198—264 V
Capacity
kW class
2.0
2.5
3.5
4.0
Input power
W
23
27
27
33
Running current
A
0.20
0.24
0.24
0.30
Fan
Airflow rate
Cooling
HIGH
m
3
/h
650
700
700
770
MED
540
560
560
600
LOW
430
430
430
450
QUIET
270
270
270
280
Heating
HIGH
720
750
770
800
MED
580
610
640
660
LOW
460
470
520
520
QUIET
330
330
330
340
Type × Q'ty
Crossflow fan × 1
Motor output
W
30
49
Sound pressure level *
1
Cooling
HIGH
dB (A)
38
40
40
43
MED
33
34
35
36
LOW
29
29
30
30
QUIET
21
21
21
21
Heating
HIGH
41
42
42
44
MED
35
36
38
39
LOW
31
31
33
33
QUIET
22
22
22
24
Sound power level
Cooling
dB (A)
54
55
57
Heating
56
57
58
59
Heat exchanger type
Dimensions (H × W × D)
mm
Main1: 210 × 670 × 26.6
Main2: 112 × 670 × 20.0
Main1: 210 × 670 × 26.6
Main2: 112 × 670 × 20.0
Sub: 84 × 670 × 13.3
Fin pitch
mm
Main1: 1.2
Main2: 1.1
Main1: 1.2
Main2: 1.1
Sub: 1.4
Rows × Stages
Main1: 2 × 10
Main2: 2 × 7
Main1: 2 × 10
Main2: 2 × 7
Sub: 1 × 4
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
KETE; White + Pearl white (painted)
Approximate color of Munsell N 9.25/
KETE-B; Dark Gray + Silver (painted)
Approximate color of Munsell 0.5P 3.5/0.2
Dimensions
(H × W × D)
Net
mm
295 × 950 × 230
Gross
284 × 1,027 × 357
Weight
Net
kg
11.0
11.5
Gross
14.5
15.0
Connection pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Gas
Ø9.52 (Ø3/8)
Method
Flare
Drain hose
Material
PP + HDPE
Tip diameter
mm
Ø13.8 (I.D.), Ø15.0 to Ø16.8 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless (Option: Wired, Mobile app*
2
[FGLair
™
])
NOTES:
• The protective function might work when using it outside the operation range.
• *
1
: Sound pressure level:
–
These are the measured values in the manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *
2
: Available on Google Play
™
store or on App Store
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
1-1. Indoor unit
- (01-16) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Summary of Contents for ABHG18KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Page 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Page 62: ......
Page 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Page 216: ......
Page 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Page 320: ......
Page 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...