FUSION SPLICER 90S Rev5
61
Special splice mode
In this mode, the parameters are set in detail and can be changed.
Use this splice mode when need to change the parameter setting, for example,
splice loss is high.
Automatic arc calibration doesn’t work in this splice mode. With this mode
selected, perform the “Arc Calibration” manually before splicing.
Database of splice mode (Special)
Splice mode
Description
SM-SM
For splicing standard SM fiber.
MFD: 9 to 10 µm, Wavelength: 1310nm, ITU-T G.652
NZ-NZ
For splicing standard NZDS fiber
MFD: 8 to 10 µm, Wavelength: 1550nm, ITU-T G.655
DS-DS
For splicing standard DS fiber
MFD: 7 to 9 µm, Wavelength: 1550nm, ITU-T G.653
MM-MM
For splicing standard MM fiber.
Core diameter: 50.0µm, 62.5 µm, ITU-T G.651
Fast splice mode
Use this mode if the fiber type is identified and prefer quick splices with high yield
to consistent splice loss.
Automatic arc calibration doesn’t work in this splice mode. With this mode
selected, perform the “Arc Calibration” manually before splicing.
Database of splice mode (Fast)
Splice mode
Description
SM FAST
For splicing standard Single-mode fiber (ITU-T G652).
The MFD is 9 to 10 um at wavelength of 1310 nm.
Automatic arc calibration doesn’t work in this splice mode.
Execute [Arc Calibration] before splicing.
NZ FAST
For splicing Non-zero dispersion-shifted fiber (ITU-T G655).
The MFD is 8 to 10 um at wavelength of 1550 nm.
Automatic arc calibration doesn’t work in this splice mode.
Execute [Arc Calibration] before splicing.
DS FAST
For splicing Dispersion-shifted fiber (ITU-T G653).
The MFD is 7 to 9 um at wavelength near 1550 nm.
Automatic arc calibration doesn’t work in this splice mode.
Execute [Arc Calibration] before splicing.
MM FAST
For splicing Multi-mode fiber (ITU-T G651).
Core diameter : 50.0 to 62.5 um
Automatic arc calibration does not work in this mode.
Execute [Arc Calibration] before splicing.