FUSION SPLICER 90S Rev5
81
Battery Discharge
This function can discharge the battery pack.
If the battery indicator and the actual capacity differ, perform this function to
readjust the battery indicator.
When executing, the fusion splicer uses the heater to discharge the battery pack.
Motor Drive
Some fusion splicer motors can be manually operated individually. When
splicing, the motors can also be operated by calling this menu in a [PAUSE], or
[FINISH] state.
1.
Select the Motor Drive icon.
2.
The name of the selected motor is displayed in the bottom section of the
screen. Select the motor by using icon.
3.
Press the up/down arrows to drive the motor in the desired direction.
Motor
UP arrow icon
DOWN arrow icon
ZL/ZR
Forward
Backward
X/Y
Upward
Downward
Focus X/Y
Close to the fiber
Far from the fiber
Wind Protector
Open Wind Protector
Close Wind Protector
Maintenance Info
The maintenance information is displayed in the Maintenance Info screen.
When pressing Next Page icon, “Software License” page appears.
When selecting [Maintenance Info], the following information is displayed:
Parameter
Description
Serial Num.
Displays the serial number of the fusion splicer.
Version
Displays the software version.
Arc Count
Displays the number of arc discharges since electrode
replacement. Performing the function [Replace Electrodes]
or [Clear Arc Count] resets this parameter to zero.
Total Count
Displays the total number of arc discharges.
Last Authorized
Service
Displays the date of last authorized service.
Next Authorized
Service
Displays the scheduled date of next authorized service.
Cleave Count
Displays the total number of Cleaves.
Blade Position
Displays the current Blade Position.
Blade Height
Displays the current Blade Height.
During this function, the fusion splicer uses the heater to discharge
the battery pack. Therefore, the fusion splicer body around the
heater may be hot. Take care not to injure your figure by the heater.
When the motor reaches the limit of the operating range, the buzzer
sounds and the motor stops. Press the opposite arrow key to reverse and
move the motor again.
If the motors are moved too much after splicing, the fiber may break.