FUSION SPLICER 90S Rev5
101
(7)
Error message can be over-ridden
・
See Section [Splice Settings] to not allow error message override.
(8)
Unable to change Arc Power and Arc Time
・
The settings cannot be changed in AUTO modes.
・
If using the “Special Mode”, the Arc Power and Arc Time may be locked by
administrator, preventing them from being changed.
(9)
Method to set Pause
・
See Section [Splice Menu] in [Splice Mode].
(10)
Method to display Cleave Angle, Fiber Angle / Offsets
・
See Section [Splice Menu]. The fiber angle is not displayable in the SM, DS,
MM or AUTO mode.
(11)
Incorrect splice mode selected and used in AUTO mode
・
The AUTO mode can detect only standard SM, DS, MM and NZDS fibers.
When splicing specialty fibers, the AUTO mode may identify them incorrectly.
Tube-heating Operation
(1)
Fiber protection sleeve does not shrink completely
・
Fiber protection sleeve might not be set to the tube heater properly.
・
When setting the fiber to the heater, do not remove hands from the fiber until
the heater cover closes and the buzzer sounds. If releasing hands from the
fiber rapidly, the protection sleeve may not be set to the heatable position.
・
If the protection sleeve is not centered between yellow lines, the protection
sleeve might not shrink completely.
・
Extend the heating time.
・
Refer to [Heater Mode].
(2)
Heater LED on panel keyboard blinks
・
Pressing the HEAT key during heating causes the LED to blink. The tube heater
is turned off if the HEAT key is pressed again. If, after 2 seconds have gone by
without pressing the HEAT key again, the LED stays on continuously and the
heater returns to its normal state. The LED will turn off when the heat cycle is
completed.
・
If the heater does not reach the current mode’s temperature value, the LED
blinks and the alarm sounds. If this happens, contact the nearest Fujikura
authorized distributor.
(3)
Fiber protection sleeve adhered to heating plate after shrink
・
Use a cotton swab or a similar soft tip object to push and remove the protection
sleeve. If the black coating is removed, contact the nearest Fujikura authorized
distributor.
(4)
Method to initialize heating condition of Heater mode
・
See Section [Referring to or editing Heater Mode].
(5)
Method to cancel heating process
・
RESET key does not cancel the heater. Press HEAT key twice to cancel the
heating process.
Wireless data communication
(1)
Wireless data communication is unsuccessful.
・
Check the power of each device to ensure it is “ON”. If it is “Off”, turn the device
“ON”.
・
Check the Link LED of each device. If it is not lit, push and hold the Link button
on each device this will cause the Link LED of the device to light and start the
paring process.
・
Check the [Splicer] and [Stripper], [Cleaver] in Bluetooth menu of the fusion
splicer. If they are “Off”, turn them “ON”.
・
RS02/03, CT50 are already connected with the fusion splicer. Push and hold the
Link button on the device. This will cause the Link LED of the device to blink and
start the paring process. After this, try to connect with the stripper. Refer to
Wireless data communication section.