FUSION SPLICER 90S Rev5
90
Cleaver Setting Menu
This menu enables parameter selection to control the splicer interface with the
CT50 cleaver.
List of the Cleaver Settings parameters (1 of 2)
Parameter
Description
Blade Setting
Blade Position
Shows the cleaved fiber count at all blade positions of
the cleaver (48 positions) while the splicer is connected
to the cleaver.
Blade Rotation Link to
Alarm
Determines the splicer's response when it detects a
cleaver blade position is worn. There are 3 options:
“Auto Without Confirmation”:
The splicer rotates the cleaver blade automatically
without notifying or seeking confirmation from the
operator.
"Auto With Confirmation":
Displays the message “Cleaver blade is worn.
Rotate to new position?”
If the operator selects [Yes], the splicer will rotate
the cleaver blade.
If the operator selects [No], the splicer will not
rotate
the cleaver blade.
"OFF": The splicer does not rotate the blade.
List of the Cleaver Settings parameters (2 of 2)
Parameter
Description
Alarm Settings
Blade Position
Change
ON/OFF setting enables or disables display of each
warning message for cleaver blade wear. If “OFF” is
selected for an alarm, no warning is indicated on the
READY screen. If “ON” is selected, the alarm will be
displayed for the operator when required.
Blade Height
Change
Blade Replacement
Blade Alarm
Detection
Selects the judgment criteria for the cleaver blade
wear and blade rotation alarm according to the
following three options:
“Cleaving Count”: Rotation alarm is based on the
number of cleaved fibers at the
current blade position.
“Image Analysis”: Rotation alarm is based on the
number of cleaving errors that
occur during the specified number
of cleaves.
“OFF”: Does not execute Blade Alarm Detection.
Number of Cleaving
Errors
These parameters set the criteria for the cleaver
blade alarm.
Example: If the “Number of Cleaving Errors” is set to
3 and the “Number of Cleaves” is set to 10, the
cleaver blade alarm window will be displayed if 3
cleaving errors occur with the most recent 10
cleaves.
Number of Cleaves
Incorrect Blade
Position
ON/OFF setting enables or disables the warning that
the cleaver blade height is wrong. If “OFF” is
selected, no warning is displayed.
Low Battery
Sets the value for remaining cleaver battery capacity
before replacement. The splicer communicates with
the cleaver to monitor the battery status and inform
the operator of the need for cleaver battery
replacement.
Others
Error Indicator on
Cleaver
ON/OFF setup of the display of cleaver error
warnings on the cleaver.
If “OFF” is selected, no warning is displayed on the
cleaver.
Device Name
Sets the device name of the CT50 cleaver that is
linked to the splicer by Bluetooth.