FUSION SPLICER 90S Rev5
68
Parameter list (5 of 5)
Parameter
Description
Error Limit
Cleave Angle
Limit
An error message is displayed if the cleave angle of either
the left or right fiber ends exceeds the selected threshold
(cleave limit). “OFF”: Does not make judgment on cleave
angle.
Cleave Shape
Error
Error message is displayed if the cleaved end face of either
left or right fiber exceeds the selected threshold (cleave
shape). “OFF”: Does not make judgment on cleave shape.
Fiber Angle
Limit
An error message is displayed if the bend angle of the two
fibers spliced exceeds the selected threshold (Fiber Angle
Limit). “OFF”: Does not make judgment on fiber angle.
Loss Limit
An error message is displayed if the estimated splice loss
exceeds selected threshold (loss limit).
Bubble
Sensitivity
An error message is displayed if the bubble of fiber exceeds
the selected threshold (bubble).
Stripper
Heat
Temperature
Level
These are stripper parameters. They are automatically sent to
the stripper if [Heater Parameter Control] in “Stripper Setting”
menu is set to “Splice Mode”. See the detail in “Bluetooth”
section.
Heat Finish
Time
Manual Splice Mode
This mode is to manually align and splice fibers. The following procedure is
required, and is different from standard automatic splicing.
1.
Select a splice mode that allows the
splice parameter [Align] in page two of
splice mode edit menu to be changed to
“manual” (i.e. SM-SM mode).
2.
Press the SET key to drive the fibers
forward. The fibers stop moving forward
at the Gapset position.
3.
Select a motor by pressing the arrow
icon
on the “PAUSE 2” screen.
4.
Press this icon to switch the
motor speed Fast or Slow.
5.
Press the
Up/Down
key to move the
selected motor and change the image
or position of the fiber.
6.
After manual alignment is completed, press SET key to arc and splice
the fibers.
Motor
Up Arrow key
Down Arrow key
ZL/ZR
Forward
Backward
X/Y
Upward
Downward
Focus X
Focus Y
Lens moves
nearer fiber.
Lens moves away from
fiber.
Menu changes when [Splice Mode] is set to [** AUTO] or [**
FAST]
The fusion splicer beeps if motor reaches its limit and stops.
Press the opposite arrow key to move the motor again.
Select a
motor
Switch the speed