FUSION SPLICER 90S Rev5
43
Heating protection sleeve
When using 60mm length sleeve
The sheath clamp is optimized for the 60mm length sleeve. In case of using
60mm length sleeve, it is easy to position the center of the protection sleeve
over the splice point.
1.
S
plice finishes and wind protector opens. “Fiber retention clamp” holds
fiber.
2.
Hold the left fiber at the end of sheath clamp shown below.
3.
Tilt the fiber to slide the
protection sleeve toward the left while maintaining
tension.
4.
The protection sleeve slides and reaches your left hand.
5.
Slide your left hand left. Keep your right hand in the same position.
6.
Move to the heater.