FUSION SPLICER 90S Rev5
82
Splice Settings Menu
Composition of the Splice Settings Menu
Common parameters for all splice modes can be set.
[Splice Settings] screen appears when selecting the Splice Settings icon at
[READY] screen.
How to change the settings
1.
The setting category is displayed on the left side. The parameters included in
the category are displayed on the right side.
2.
Select and change the category icon and find the target parameter.
3.
Select the parameter displayed on the right side, to show the parameter edit
screen.
4.
Select and change the target parameter.
List of Splicing Settings parameters (1 of 2)
Parameter
description
Fundamental settings
Operation
Mode
Automated wind-protector has several operation modes.
Pause1
If "Pause1” is set to “ON”, the splicing operation pauses when
fibers are forwarded to gap-set position. Cleave angles are
displayed during the pause.
Pause2
If “Pause 2” is set to "ON", the splicing operation pauses after
fiber alignment is completed. With ECF “ON”, core-to-core
alignment is made after this pause.
Splice Memory
Comment
A comment can be added to the memory saved at the time of
the end of connection.
Heater Menu
Auto Cover
Open
Select the heater cover motion.
[ON]: The heater cover opens except for heating operation.
[OFF]: The heater cover closes except for pressing the HEAT
key.
Cover Close
Time
The heater cover automatically closes if it performs no
operation after “Cover Close Time”.
[Max Value]: 1000sec
[OFF]: The heater cover does not close automatically. It is
recommends to use this to prevent a dust with inserting
inside.