How to charge the battery
Plug the AC power cord (ACC-xx) into the inlet of the AC adapter (ADC-20).
Plug the supply terminal of AC adapter into the inlet of the battery pack (BTR-
15).
While charging, do not place the battery on top of AC adapter or vise-versa.
Battery charge is completed in approximately five to eight hours. However, it
takes more depending on the environmental.
After completion, disconnect the supply terminal of AC adapter and AC power
cord.
The battery can be charge while splicer is in use. Installed BTR-15 into power dock,
and then connect to AC adaptor, ADC-20 or DC power cord.
AC adapter
AC power cord
Battery pack
The battery pack can be charged with AC and DC.
Do not place battery on top of AC adapter or vise-versa.
The battery can be charge while the fusion splicer is in use.
Installed BTR-15 into power dock and connect to AC adaptor,
ADC-20 or DC cord.
If battery charge does not complete or LED indicator of BTR-
15 does not light up, AC adapter or both need replacement.