FUSION SPLICER 90S Rev5
34
Lock
Preparation of fiber
Cleaning optical fiber
Clean optical fiber with alcohol-moistened gauze or lint-free tissue approximately
500mm from the tip. Dust and particulates from the fiber coating can enter inside
the protection sleeve and might result in a future fiber break or transmission
attenuation.
Placing protection sleeve over fiber
Place the protection sleeve over the Right side fiber.
Fiber coating stripping and cleaning of bare fiber
Strip the outer coating 30 to 40 mm from fiber tip with a stripping tool. Clean the
fiber with alcohol moistened gauze or lint-free tissue thoroughly. Frequently
replace cleaning gauze to insure splice quality.
Fiber Cleaving when using a sheath clamp
1.
Take out the CT50 from the carrying case and release the lock from the lever.
2.
Lift the lever until it stops. The blade is automatically set at the start
position and is now ready to cleave the fiber.
3.
Open the lid of the fiber plate AD-10-M24. Set the cleaned fiber onto the
fiber plate. Check and adjust the fiber length using the scale on the fiber
plate.
Following the convention of the operator holding the left fiber in
their left hand, place the protection sleeve on the right side of the
fiber.
Fiber protection sleeve
Pass fiber
Fiber
Stripping
Cleaning
AD-10-M24
Scale
Adjust the cleaving length
by using the scale
Use a high quality alcohol, greater than 99% purity.