FUSION SPLICER 90S Rev5
97
Error Message List (3 of 8)
Error
Message
Reason
Solution
ZL/R
X/Y
Focus X/Y
Cover F/R
Heater
Motor trouble
・
Motor might be damaged.
・
Consult the nearest Fujikura
authorized distributor.
Cannot detect
fiber
in
AUTO mode
・
Dust or dirt is on the fiber
surface.
・
Completely prepare the fiber
again (strip, clean and
cleave).Select the suitable
splice mode.
・
The left and right fiber
types are different.
・
Splicing non-standard
fibers.
Strong
Arc Power
・
Unable to calibrate due to
strong arc.
・
Replace the electrodes by
using the [Replace
Electrodes] function in. If
this does not eliminate the
problem, consult the nearest
Fujikura authorized
distributor.
Weak
Arc Power
・
Unable to calibrate due to
weak arc.
Too Left
/Right Arc
・
Unable to calibrate due to
poor arc field position (too
far left or Right).
Fiber
Separation
・
The fiber stuff amount is
insufficient.
・
Execute the [Motor
Calibration] function. If
using other splice modes,
check the [Overlap] setting in
the splice mode.
・
The pre-fuse power or pre-
fuse time is set too high.
・
Check the [Prefuse Power]
and [Prefuse Time] settings
in the splice mode.
L/R-Bad Fiber
Position
・
The fiber is not set
correctly at the bottom of
the V-groove.
・
Press RESET key, and re-
position the fiber again to
seat it correctly at the bottom
of the V-groove.
Error Message List (4 of 8)
Error Message Reason
Solution
No Arc
Discharge
・
Arc Discharge did not
occur.
・
Assure the electrodes are in
proper position.
・
Replace the electrodes.
・
Consult the nearest Fujikura
authorized distributor.
Large
Cleave
Angle
・
Bad fiber end-face.
・
Check the condition of the fiber
cleaver. If the blade is worn,
rotate the blade to a new
position.
・
[Cleave Limit] is set too
low.
・
Increase the [Cleave Limit] to
an adequate limit.
Large
Fiber
Angle
・
Dust or dirt is on the V-
groove or the clamp
chip.
・
Clean the V-groove and clamp
chip, and set the fibers again.
If the error occurs again, strip,
clean and cleave the fibers.
・
Bad fiber end-face.
・
Check the condition of fiber
cleaver. If the blade is worn,
rotate the blade to a new
position.
Cleave Shape
NG
・
Bad fiber end-face.
・
Check the condition of fiber
cleaver. If the blade is worn,
rotate the blade to a new
position.
Arc Discharge
Delayed
・
Arc Discharge is
delayed
・
Assure the electrodes are in
proper position.
・
Execute the [Stabilize
Electrode] function.
・
Replace the electrodes.