FUSION SPLICER 90S Rev5
95
Error Message List
Press ENT when an error is shown on the monitor. The [HELP] screen displays
the following:
When an error is in the list below, the fusion splicer repeats the alignment when
the operator presses the SET key.
・
L-Too Long Fiber
・
R-Too Long Fiber
・
LR-Too Long Fiber
・
L-Too Dusty Fiber
・
R-Too Dusty Fiber
・
ZL Motor Overrun (Forward)
・
ZR Motor Overrun (Forward)
・
ZL Motor Overrun (Backward)
・
X Motor Overrun
・
Y Motor Overrun
・
Focus-X Motor Overrun
・
Focus-Y Motor Overrun
・
Cannot detect fiber (in AUTO mode)
・
L/R-Bad Fiber Position
When an error is in the list below, the fusion splicer carries out operation which
changes with preset values of “Ignore Splicing Error”, when the operator presses
the SET key.
See Section [Splice Settings].
・
Large Cleave Angle
・
Cleave Shape NG
・
Thin
・
Fat
・
Bubble
・
Dust Burned
・
High Loss Estimated
Follow the solution precisely as shown in the list below. If it is not possible to
eliminate the problem, the fusion splicer may require service by a qualified
service center. Consult the nearest Fujikura authorized distributor with the
following information:
・
Model name of the fusion splicer
・
Serial number of the fusion splicer
・
Error message
・
Situation when the error occurs
-Video or picture if possible