M6500 Series NE Configuration Manual
89
Select NE-Slot 2, click on “
Port 3
”and select“
Port Management
”on the right, and then select OCh (OTU4) as the
port mode. In“
OTU4
”interface under“
Port Configuration
”, select “
FEC type
”to view the configuration. There are in
all 7 FEC modes for TMXP2 line side, which are respectively
G709FEC/SDFEC1/SDFEC2/SDFEC3/SDFEC1_Non-diff/SDFEC2_Non-diff/SDFEC3_Non-diff. SDFEC3 is the default
mode, as shown in the figure below:
Figure5-51 FEC Configuration of M6500-TMXP2 Line Side Port
Client Side 100G Port
Select NE-Slot 2, click on “
Port1
”and select“
Port Management
”on the right”, and then select OTU4 as the port
mode. In“
OTU4
” interface under“
Port Configuration
”, select “
FEC type
”to view the configuration. There is only
one default FEC mode for 100G client side, which is G709FEC, as shown in the figure below:
Figure5-52 FEC Configuration of M6500-TMXP2 Client Side 100G Port
Client Side 40G Port
Select NE-Slot 2, click on“
Port1
”and select“
Port Management
”on the right, and then select OTU3 as the port
mode. In“
OTU3
” interface under “
Port Configuration
”, select “
FEC type
”to view the configuration. There are in all 4
FEC modes for the client side 40G, which are respectively No FEC/G709FEC/I.4EFEC/I.7EFEC. G709FEC is the
default mode, the configuration is as shown in the figure below:
Summary of Contents for M6500 Series
Page 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Page 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Page 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Page 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Page 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Page 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...