M6500 Series NE Configuration Manual
139
Figure8-17 Delete History Alarm
The function of“
Delete All
”button is to delete all the history alarms.
The function of“
Export
”button is to export all the history alarms. A dialog box pops up after clicking
the Export button. Enter the name of the file you want to save in the dialog box. After saving, it will
prompt to save the path. The exported data is saved in Excel format.
Figure8-18 Export History Alarm
The path to save the data is: NMS Installation Root Directory
→
report_out Folder
→
HistoryAlarm Folder
→
File
Name.xls.
The lower area of the navigation bar is the display section of the history alarm. From left to right in turn, the
table header is: Serial Number, NE, Alarm Source, Alarm Name, Alarm Type, Severity, status, Raised Time, Cleared