M6500 Series NE Configuration Manual
47
Figure4-6 Board Information Interface
4.4. Port Configuration
Select NE-Slot1 click on“
Port1
”, and then select“
Port Management
”on the right
,
as shown in the figure below:
Figure4-7 View Port Configuration Information
4.4.1. Basic Information
There are two port types: client side port and line side (system side) port.
Client side port type supports: FE, GE, 10GE, 40GE, and 100GE, STM-1/4/16, OC-3/12/48, STM-64, OC-192 and
OTU2 (2e)/OTU3/OTU4.
For line side (system side) port type, the grey light supports OTU2/2e and OTU4, and the color light supports
OCh (OTU2/2e) and OCh (OTU4).
Select NE-Slot 1, click on“
Port1
”, and select“
Port Management
”on the right, the interface as shown in the figure
below pops up. The configuration status and port mode can be modified in basic information.