M6500 Series NE Configuration Manual
175
Performance Monitoring Point: There are near end and far end, as well as entrance and exit for OTUk/ODUk
monitoring points.
Performance Monitoring Parameters: background error code block (BBE), bit error seconds (ES), serious bit error
seconds (SES) and unavailable seconds.
Figure9-80 OTUk/ODUk History Performance Parameters
9.3.4.2. View OTUk/ODUk History Monitoring Information
15minutes and 24hours of OTUk/ODUk history data operation and display are the same form. Here we take
15-minute OTUk/ODUk history monitoring point as an example. Choose the appropriate network elements,
slots, ports and monitoring cycles through the screening box above the menu, and then select the time interval,
performance monitoring point and parameters which need to be monitored in the right menu.Parameters to be
monitored can be all selected or only select one or two of them to check.After that, click Apply button on the
lower right corner. From the graph, we can see the trend of the refraction chart of the monitoring parameters.
The ordinate represents the value of the monitoring data, and the abscissa represents the time. Data which has
been read for more than 15 minutes will be automatically transferred from current statistics to history statistics.
Figure9-81 15-Minute Chart Data of OTUk/ODUk
History performance statistics of OTUk/ODUk also show history data in tabular form. Click on the table, the
interface as shown in the figure below appears:
Summary of Contents for M6500 Series
Page 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Page 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Page 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Page 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Page 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Page 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...