M6500 Series NE Configuration Manual
99
Line side port
Select NE-Slot 1, click on "
Port1
" and select "
Port Management
" on the right, select OCh (OTUC2) or OCh (OTU4)
as the port mode, select "
OTUC2
" or "
OTU4
" under "
Port Configuration
" and "
FEC Type
" option, check the
configuration. When the line side is in 2*100G mode, there are a total of 6 FEC modes on the M6500-TMXP5 line
side, which are
SDFEC1_8QAM/SDFEC2_8QAM/SDFEC3_8QAM/SDFEC1_16QAM/SDFEC2_16QAM/SDFEC3_16QAM, and when
the line side is 7 in the default mode, SDFEC3_16QAM is the default mode. The FEC modes are
G709FEC/SDFEC1/SDFEC2/SDFEC3/SDFEC1_Non_diff/SDFEC2_Non_diff/SDFEC3_Non_diff, and SDFEC3 is the
default mode. As shown below.
Figure5-73 M6500-TMXP5 Line side port FEC configuration
Client Side 100G port
Select the NE-Slot 1, click on "
Port1
" and select "
Port Management
" on the right, select OTU4 as the port mode,
and select the "
FEC Type
" option on the "
OTU4
" interface under "
Port Configuration
" to view the configuration ,
Summary of Contents for M6500 Series
Page 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Page 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Page 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Page 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Page 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Page 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...