M6500 Series NE Configuration Manual
114
Figure6-15 Set Client Side PM Overhead
TTI Configuration
Enter“ODU2”/“ODU2e”interface of line side local and opposite ends to configure “Expected Receiving TTI”of
“PM” overhead for the corresponding port and to monitor whether the line side receiving signal is correct.
Configure the expected source access point identifier (SAPI) and expected destination access point identifier
(DAPI) (Here ODU2/ODU2e is prohibited to set sent SAPI and DAPI).
Enter“ODU2”/“ODU2e”interface of the client side local and opposite ends to configure “expected receiving
TTI”and“sending TTI”of “PM” overhead for the corresponding port. Configure the expected source access point
identifier and sent source access point identifier (SAPI), as well as expected destination access point identifier
and sent destination access point identifier (DAPI). The TTI configuration steps of the opposite end are the same
as those of the local end. Here we will not go into too much detail.