6 Mounting
6.2 Transducers
FLUXUS G831ST-HT
2021-06-01, UMFLUXUS_G831ST-HTV1-0EN
30
6.2.2.4
Mounting with Variofix L (PermaRail)
Mounting
For measurements in diagonal arrangement, the transducer mounting fixtures are mounted on opposite sides of the pipe.
Mounting the transducer pairs in one pair of rails is not possible when using Variofix L. In the following, the installation of
2 pairs of rails in diagonal arrangement is described (each transducer pair in its own pair of rails).
Overview of the mounting steps
•
step 1
disassembly of the transducer mounting fixture Variofix L
•
step 2
fixation of the clasps to the tension straps
•
step 3
fixation of the tension strap to the pipe
•
step 4
fixation of the rail to the pipe
•
step 5
installation of the transducers in the mounting fixture Variofix L
Step 1: Disassembly of the transducer mounting fixture Variofix L
• Disassemble the transducer mounting fixture Variofix L.
Fig. 6.6:
Transducer mounting fixture Variofix L
Fig. 6.7:
Disassembly of the transducer mounting fixture Variofix L
1 – cover
2 – screw
3 – nut
4 – rail
5 – tension strap clamp
1
2
3
4
5
5