15 Data logger
FLUXUS G831ST-HT
15.2 Deletion of the data logger
119
UMFLUXUS_G831ST-HTV1-0EN, 2021-06-01
15.2
Deletion of the data logger
• Select the menu item
Delete meas. values
.
• Press ENTER.
• Select
Yes
or
No
.
• Press ENTER.
15.3
Information regarding the data logger
• Select the menu item
Data logger info
.
• Press ENTER.
The following information regarding the data logger is displayed:
Special functions\Data logger\Delete meas. values
Special functions\Data logger\Data logger info
display
description
Activated
data logger is activated/deactivated
This display will only be indicated if the measurement has started and the data logger is activated.
Full (date)
date on which the data logger will be full
This display will only be indicated if the measurement has started and the ringbuffer is deactivated.
Full (time)
time at which the data logger will be full
This display will only be indicated if the measurement has started, the ringbuffer is deactivated and
the data logger is not full yet.
Overflow (date)
date from which the oldest measured values will be overwritten
This display will only be indicated if the measurement has started, the ringbuffer is activated and the
data logger is not full yet.
Capacity (time)
remaining data logger capacity
This display will only be indicated if the measurement has started and the ringbuffer is activated.
Ringbuffer
ringbuffer is activated/deactivated
Meas. val. Series
number of stored series of measured values
Occup. Logger
percentage of memory actually used