6 Mounting
FLUXUS G831ST-HT
6.2 Transducers
35
UMFLUXUS_G831ST-HTV1-0EN, 2021-06-01
Band clamp clasp
• Insert the tension strap into the tension strap clamp (2).
• Place the tension strap around the pipe and insert it into the tension strap clamp on the opposite side and the tension
strap (see Fig. 6.19 and Fig. 6.20).
• Tighten the tension strap.
• Tighten the clasp screw.
• Tighten the nuts of the tension strap clamps (2), but not too firmly in order not to damage the tension strap.
Quick release clasp
• Insert the tension strap into the tension strap clamp (2) and the metal spring.
• Place the tension strap around the pipe and insert it into the tension strap clamp on the opposite side and the tension
strap (see Fig. 6.19 and Fig. 6.21).
• Position the metal spring opposite the clasp.
• Tighten the tension strap.
• Tighten the clasp screw.
• Tighten the nuts of the tension strap clamps (2), but not too firmly in order not to damage the tension strap.
Fig. 6.19: Rail on the pipe
1 – tension strap clamp
2 – tension strap clamp
3 – metal spring
4 – nut
5 – clasp
Fig. 6.20: Tension strap with band clamp
clasp
Fig. 6.21: Tension strap with quick release
clasp and metal spring
1 – clasp screw
1 – clasp screw
2 – metal spring
3
4
2
5
1
1
2
1