6 Mounting
6.2 Transducers
FLUXUS G831ST-HT
2021-06-01, UMFLUXUS_G831ST-HTV1-0EN
34
Step 4: Fixation of the rail to the pipe
• Place the tension strap clamp (2) in the rail, see Fig. 6.17. Observe the orientation of the tension strap clamp.
• Slightly tighten the nut of the tension strap clamp (2).
• Screw the rail to tension strap clamp (1), see Fig. 6.18.
• Tighten the nut of tension strap clamp (1), but not too firmly in order not to damage the tension strap.
• Repeat the steps to fix the second rail on the opposite side of the pipe. Make sure that both tension strap clamps are as
exactly as possible opposite each other. To do this, check whether the distance between the tension strap clamps is half
the pipe circumference.
• Select the installation instruction of the supplied clasp:
Fig. 6.16: Ratchet clasp with tension strap
1 – sense of rotation
2 – edge
3 – lever
4 – clasp screw with slot
Fig. 6.17: Rail with tension strap clamp
1 – nut
2 – tension strap clamp
Fig. 6.18: Rail, fixed on one side to the pipe
1 – tension strap clamp
2 – tension strap clamp
3 – nut
1
2
4
3
4
1
2
2
1
3
1