73
7. Then assign the appropriate length of time
the “<” and “>”keys in the second box.
Assign timing for each size.
Back
Done
Serving Times
Setup
Small
1.2 secs
26598
8. Repeat Steps 6 and 7 to set timing for the
other sizes.
9. Press the DONE key in the upper right
corner of the screen.
Done
26508
10. Test out each serving size and repeat
instructions to make any adjustments.
26289
SMALL
MEDIUM
EXTRA LARGE
LARGE
Adjusting the End of Serving Delay Timing
When the system is in the Timed Serving Size
or Auto Dispense Mode, the syrup pump shuts
off moments before the serving size alarm
beeps. This feature allows unflavored product
to pass through the Blending Head and clears
out the flavoring so there is less carryover to
the next serving. Depending on your freezer’s
product flow rate, you may need more or less
time between the syrup shut-off and the serving
size alarm. This can be adjusted using the
following directions.
1. From the main menu screen, press the
SETUP key in the upper left corner. Enter
the password if required.
Injector Flush
Chocolate Swirl
Strawberry
Butter Pecan
Classic Cherry
Banana Ripple
Green Apple
Blue Goo
Purple Grape
Setup
26501
2. Press the MAINTENANCE key.
Exit
Setup and Maintenance
System Setup
Maintenance
26531
3. Press the TIMING SETTINGS key.
Back
Done
Maintenance
Setup Options
Prime Syrup Pump
Serving Counter
Timing Settings
Water/Syrup Flush
Menu Setup
Adjust Dispense Rate