52
8. For freezers with a flat draw-handle bar, an
external switch assembly is included in the
spare parts kit. To install this Spigot Switch
assembly, simply clip the Switch Bracket
onto the handle and slide it up the handle
until the switch is within grasping range.
26154
9. Then, connect the switch extension to the
Spigot Switch jack and ensure the
connection is fully engaged.
NOTE:
IF YOUR FREEZER DOES NOT HAVE
AN INTERNAL SWITCH JACK AND THE
SPARE DRAW HANDLE SWITCH DOES NOT
FIT YOUR FREEZER, CONTACT YOUR
LOCAL DISTRIBUTOR FOR MORE OPTIONS.
Sanitizing the Blending System
If the Blending Assembly is already assembled,
disassemble it according to instructions in the
DAILY CLOSING PROCEDURES.
1. Prepare approved sanitizer solution
according to manufacturer’s instructions.
2. Place the Gear Box, Suspension Bracket,
Gear Cartridge, Spout Adapter, and
Blending Head in approved sanitizer
solution and soak for 1 minute.
26066
3. Remove each part from the sanitizer
solution. Place the items on a sanitary tray
to air dry.
26067
4. Remove the cap and spray the cap and
Syrup Line Manifold opening with approved
sanitizer solution. Allow them to sanitize for
at least 1 minute.
26068
5. Place the 9-Tube Assembly and Manifold
cap on a sanitary tray to dry.