Règle de montage 2
Maintenance
Check the wear of the brushes periodically: the base of the chamfer is to be used as the indicator of the limit of wear. The average
operating life of the brushes is of 2000 km. After the installation has been cut off from mains, pull up the collector box to take it out
of the rail. Collector 200A: Pull up the brush to take it out of the box of pantograph and unscrew the bolted connection with the
cable, Check that the cable eye stiffener is correctly fitted when reassembling! Replacement of 200A brush: the limit of wear is the
base of the chamfer. Collector 60A: Loosen and take the connection screw out of the brush, Remove the worn brush, fit the new one
and
proceed
in
reverse
order.
www.fels.fr
|
T +33(0)3 88 67 10 60
|
F +33 (0)3 88 55 01 79
|
Edité le 04/01/2017
Page 189/223