6. INSULATION DISTANCES:
The insulation distance between conductors or between conductors and accessible parts:
- Distance in the air: 10 mm min.
- Creepage distance: 30 mm min. (according to Standard EN60204-32).
7. FLAME RESISTANCE:
All materials used to build Mobilis Movit lines are self-extinguishing; they pass successfully
glowing/hot line tests under 960°C for elements in contact with live parts and V-0 according to
UL-94.
8. SAFETY PINS
Rail: The ground rail is marked on the line with a green-yellow band. The ground conductor should
be installed on the outer side.
Collector: with the safety pin system, it is not possible to insert a ground collector trolley
incorrectly (on phase), leading to a phase-earth connection.
9. SPACE REQUIREMENTS :
Mobilis Movit Technical Data