Retorque
WRS
Pump
Head
Screws
CHECK
TASK
1.
Ensure
the
WRS
is
disconnected
from
the
SMU
and
is
accessible
from
all
sides.
2.
Remove
the
Front
Panel
(panel
closest
to
bulkhead
end)
to
expose
the
motor.
3.
Using
a
10
mm
socket
and
torque
wrench
set
to
108
in
‐
lbs.,
torque
the
4
pump
head
bolts
(See
Section
4.5
Interior
Components
Diagrams
for
location).
4.
Replace
the
Front
Panel,
reconnect
the
WRS,
and
verify
proper
operation
of
the
WRS
by
pumping
water
into
the
SMU.
WRS
Breather
&
PSV
Inspection
CHECK
TASK
1.
Ensure
the
WRS
is
disconnected
from
the
SMU
and
is
accessible
from
all
sides.
2.
Remove
the
Top
Panel.
3.
Remove
the
Bleach
Fill
Port
and
Breather
Plug
(See
Section
4.5
Interior
Components
Diagrams
for
location)
and
inspect
that
air
can
freely
pass
through
the
breather
and
that
the
breather
is
not
clogged
with
debris.
4.
If
necessary,
clean
the
breather
plug
by
using
compressed
air.
5.
Reinstall
the
breather
plug.
6.
Pull
the
Tank
Pressure
Relief
Valve
ring
(See
Section
4.5
Interior
Components
Diagrams
for
location)
and
verify
that
the
poppet
moves
freely
and
re
‐
seats.
7.
Replace
the
Top
Panel.
80
Summary of Contents for P2131
Page 121: ... THIS PAGE INTENTIONALLY LEFT BLANK 115 ...
Page 130: ...SECTION A APPENDIX 124 ...
Page 131: ...A 1 Swagelok Fitting Installation Instructions 125 ...
Page 135: ...A 2 PLC Data Sheet 129 ...
Page 141: ...A 3 VERIFY Product Information 135 ...
Page 147: ...A 4 WRS Pump Information 141 ...
Page 158: ...A 5 Vacuum Leak Test Troubleshooting Guide 152 ...