60
5 Parameter description
5.1 Basic setting commands
5.1.4 Configuration of fault pin and digital inputs
Command
Argument
Function
Description
ERROUT
–
Error Output
Fault pin as error output
ENCOUT
–
Encoder Output
Fault pin as pulse output (not for MCDC):
DIGOUT
–
Digital Output
Fault pin as digital output. The output is set to low level.
DIRIN
–
Direction Output
Fault pin as rotational direction input
REFIN
–
Reference Input
Fault pin as reference or limit switch input
DCE
Value
Delayed Current
Error
Delayed error output for ERROUT in 1/100 sec.
Value: 0…65 535
LPN
Value
Load Pulse Number Preset pulse number for ENCOUT.
Value: 1…255
CO
–
Clear Output
Set digital output DIGOUT to low level
SO
–
Set Output
Set digital output DIGOUT to high level
TO
–
Toggle Output
Switch to digital output DIGOUT
SETPLC
–
Set PLC inputs
Digital inputs PLC-compatible (24 V level)
SETTTL
–
Set TTL inputs
Digital inputs TTL-compatible (5 V level)
5.1.5 Configuration of homing and limit switches in
Command
Argument
Function
Description
HP
Value
Hard Polarity
Define valid edge and polarity of respective limit switches:
1: Rising edge and high level effective.
0: Falling edge and low level effective.
HB
Value
Hard Blocking
Activate Hard Blocking function for relevant limit switch.
HD
Value
Hard Direction
Presetting of direction of rotation that is blocked with HB of respective
limit switch.
1: Clockwise rotation blocked
0: Anticlockwise rotation blocked
SHA
Value
Set Home Arm-
ing for Homing
Sequence
Homing behaviour (GOHOSEQ):
Set position value to 0 at edge of respective limit switch.
SHL
Value
Set Hard Limit for
Homing Sequence
Homing behaviour (GOHOSEQ):
Stop motor at edge of respective limit switch.
SHN
Value
Set Hard Notify for
Homing Sequence
Homing behaviour (GOHOSEQ):
Send a character to RS232 at edge of respective limit switch.
HOSP
Value
Load Homing
Speed
Load speed and direction of rotation for homing (GOHOSEQ, GOHIX,
GOIX).
Value: –30 000…30 000 rpm
POHOSEQ
0 – 1
Power-On Homing
Sequence
Start homing automatically after power-on.
0: No homing after switch-on
1: Power-On Homing Sequence is activated
HA
Value
Home Arming
Set position value to 0 and delete relevant HA bit at edge of respective
limit switch. Setting is not saved.
HL
Value
Hard Limit
Stop motor and delete relevant HL bit at edge of respective limit switch.
Setting is not saved.
HN
Value
Hard Notify
Send a character to RS232 and delete relevant HN bit at edge of respec-
tive limit switch. Setting is not saved.
7
6
5
4
3
2
1
0
Analog input
Fault-Pin
3rd input
4th input
(only MCDC)
5th input
(only MCDC)