68
5 Parameter description
5.5 General query commands
Command
Argument
Function
Description
GTYP
–
Get Controller Type Query designation (name) of the controller
GSER
–
Get Serial Number Query the serial number
VER
–
Get Version
Current software version
POS
–
Get Actual Position Current actual position
TPOS
–
Get Target Position Target position
GV
–
Get Velocity
Current target velocity in rpm
GN
–
Get N
Current target velocity in rpm
GU
–
Get PWM Voltage Set PWM value in VOLTMOD
GRU
–
Get Real PWM
Voltage
Current controller output value
GCL
–
Get Current Limit
Current limitation current in mA
GRC
–
Get Real Current
Current actual current in mA
TEM
–
Get Temperature
Current housing temperature in °C
GADV
Value
Get Analog Volt-
age
Read out the voltage applied at the given input (value).
Scaling: 1000 digits = 1 V
Return value input 1: -10 000 … 10 000
Return value input 3, 4, 5: 0 … 10 000
Value: 1, 3, 4, 5 (4 and 5 for MCDC only)
OST
–
Operation Status
Display current operating status.
Return value binary coded (LSB=Bit 0):
Bit 0: Homing running
Bit 1: Program sequence running
Bit 2: Program sequence stopped because of DELAY command
Bit 3: Program sequence stopped because of NOTIFY command
Bit 4: Current limitation active
Bit 5: Deviation error
Bit 6: Overvoltage
Bit 7: Overtemperature
Bit 8: Status input 1
Bit 9: Status input 2
Bit 10: Status input 3
Bit 11: Status input 4
Bit 12: Status input 5
Bit 13 – 15: Reserved for further inputs
Bit 16: Position attained
SWS
–
Switch Status
Temporary limit switch settings.
Return value binary coded (LSB=Bit 0):
Bit 0-7: HA setting
Bit 8-15: HN setting
Bit 16-23: HL setting
Bit 24-31: Details of which limit switch has already switched
(is reset again when new setting entered at the respective input)